Understand
What is GUDID? FDA Medical Device Database Guide (2026)
Updated
GUDID is the FDA database containing identification information for devices subject to applicable UDI/GUDID requirements.
Read the guideSaudi DI · SFDA · Saudi Arabia
Updated Mandatory, phased by risk class
Not sure which other systems apply to your devices? Check my obligations →
The manufacturer, or its authorised representative in the Kingdom, submits and maintains the data. An own-brand or private labeler is considered the manufacturer for UDI purposes. Relabelers, repackagers and remanufacturers create their own UDI and their own records.
| Requirement | Who | Deadline | Source |
|---|---|---|---|
| Submit and maintain the UDI data in Saudi-DI for every device placed on the Saudi market | Manufacturer or authorised representative | UDI-DI data available when the device is placed on the market | SFDA, MDS-REQ 7, section D (opens in a new tab) |
| Update the record after a change that does not require a new UDI-DI | Manufacturer or authorised representative | Within ten working days of the change | SFDA, MDS-REQ 7, section D (opens in a new tab) |
| Validate the UDI data at submission and once a year | Manufacturer or authorised representative | Annually | SFDA, MDS-REQ 7, section D (opens in a new tab) |
| Comply by risk class, following the SFDA's phased enforcement plan | Manufacturer or authorised representative | SFDA, MDS-REQ 7, compliance dates (opens in a new tab) | |
| Devices imported before their compliance date may be distributed for one year after that date | Importer | One year after the compliance date | SFDA, MDS-REQ 7, compliance dates (opens in a new tab) |
The SFDA requirements of May 2022 state that enforcement is phased by risk class and refer to an announcement on the SFDA website for the dates; that announcement is no longer online. The 2019 guidance planned Class D six months after the launch of the database, Classes B and C one year after, and Class A two years after.
Sources: SFDA, MDS-REQ 7 of 24 May 2022, compliance dates; SFDA, MDS-G34 guidance, version 2.0 of 11 December 2019, chapter four. Read on 29 October 2026.
ACKOMAS and Saudi DI
ACKOMAS keeps a Saudi record for each device and publishes it to Saudi-DI after your validation.
Build the Saudi record from the device data you already hold: identifiers, packaging levels, labelled characteristics, Arabic fields for home-use devices. Gaps are flagged before submission.
Submit to Saudi-DI once your team has validated the record. Each submission and its status are recorded.
Update within the ten working days when the device changes, run the annual validation, and keep the history of every version.
The manufacturer or its authorised representative in the Kingdom. A private labeler is treated as the manufacturer. Source: SFDA, MDS-REQ 7.
When the device is placed on the Saudi market: the UDI-DI data must be available in the database at that moment. Changes that do not create a new UDI-DI are recorded within ten working days.
Identifiers from the three accepted issuing agencies: GS1, HIBCC and ICCBBA. The primary UDI-DI is a GTIN-14, a HIBC-LIC or an ISBT 128 PPIC.
Enforcement is phased by risk class, A to D, according to the SFDA's announcement; see the note above on compliance dates. Devices imported before their compliance date may be distributed for one year after it.
Partly. The SFDA states that some data in Saudi-DI is publicly available.
Understand
Updated
GUDID is the FDA database containing identification information for devices subject to applicable UDI/GUDID requirements.
Read the guideUnderstand
Updated
AusUDID is mandatory for Class IIb and III devices since 1 July 2026.
Read the guideAcross regulators
Updated
EUDAMED vs GUDID: key differences in scope, data models and UDI requirements, for manufacturers operating in both EU and US regulatory frameworks.
Read the guide
Tell us how many devices you place on the Saudi market and who represents you in the Kingdom. We will show you the ACKOMAS path for your case.