Understand
What is GUDID? FDA Medical Device Database Guide (2026)
Updated
GUDID is the FDA database containing identification information for devices subject to applicable UDI/GUDID requirements.
Read the guideGUDID · FDA · United States
Updated Mandatory for devices subject to the FDA UDI rule, unless an exception or alternative applies
Not sure which other systems apply to your devices? Check my obligations →
The labeler submits: the company whose name appears on the device label, which is usually the manufacturer. A third party, such as a software platform, may prepare and transmit the records, but the labeler remains responsible for the information submitted. A GUDID account, tied to the labeler's DUNS number, is required before any submission.
| Requirement | Who | Deadline | Source |
|---|---|---|---|
| Submit DI records for Class III devices and devices licensed under the Public Health Service Act | Labeler | Since 24 September 2014 | FDA, UDI rule compliance dates (opens in a new tab) |
| Submit DI records for implantable, life-supporting and life-sustaining devices | Labeler | Since 24 September 2015 | FDA, UDI rule compliance dates (opens in a new tab) |
| Submit DI records for Class II devices | Labeler | Since 24 September 2016 | FDA, UDI rule compliance dates (opens in a new tab) |
| Submit DI records for Class I and unclassified devices | Labeler | Since 24 September 2018; the FDA did not intend to enforce submission before 8 December 2022 | FDA, compliance policy of 22 July 2022 (opens in a new tab) |
| Submit through one of the two accepted routes: the GUDID web application for single records, or HL7 SPL files through the FDA Electronic Submissions Gateway for volumes | Labeler | At each submission | FDA, Submit data to GUDID (opens in a new tab) |
The FDA's Compliance Program 7382.850 for medical device inspections treats the UDI system as a regulatory requirement: inspectors compare the GUDID record with the device labelling, and a GUDID discrepancy is a quality system discrepancy. Keeping the record consistent with the label is part of the quality system, not a one-off submission.
Source: ACKOMAS guide, GUDID and the FDA Compliance Program 7382.850, published 19 March 2026. Read on 29 October 2026.
ACKOMAS and GUDID
ACKOMAS maps your device data to the GUDID data dictionary and submits the records once your team has validated them.
Build each DI record from the device data you already hold: identifiers from your issuing agency, the attributes of 21 CFR 830.310, the production identifier flags and the packaging levels. Gaps are flagged before submission.
Submit through the FDA's accepted route after your validation. Each submission and its status are recorded.
Update a record when the device changes, create a new DI when the change requires one, and keep the history of every version for inspections.
A GUDID submission is the transmission of a DI record to the FDA: the device identifier and the attributes required by 21 CFR 830.310, entered in the GUDID web application or sent as an HL7 SPL file through the Electronic Submissions Gateway. The record is published on AccessGUDID once accepted.
A GTIN is an identifier: the Global Trade Item Number issued under GS1 rules, used as the device identifier when GS1 is the issuing agency. GUDID is the database in which that identifier and the device attributes are recorded. The GTIN is the key; GUDID is the catalogue.
Yes, for every device subject to the UDI rule, unless an exception or an alternative applies. The obligation was phased in by class from 24 September 2014 to 24 September 2018, with an enforcement policy for Class I and unclassified devices until 8 December 2022. Source: FDA.
GUDID itself charges no fee per record. The cost sits elsewhere: membership of an issuing agency, the preparation of the data, and the submission route you choose, manual or automated.
No. GUDID is the submission system, reserved to labelers with an account. AccessGUDID is the public portal, run with the National Library of Medicine, where anyone can search and download the published records.
Yes. The FDA accepts HL7 SPL files through the Electronic Submissions Gateway, which is the route for volumes. A third party can prepare and transmit the files; the labeler remains responsible for their content.
Understand
Updated
GUDID is the FDA database containing identification information for devices subject to applicable UDI/GUDID requirements.
Read the guideAcross regulators
Updated
FDA Compliance Program 7382.850 makes GUDID an inspectable part of manufacturer evaluations: how inspectors use UDI data, and why gaps become QMS findings.
Read the guideAcross regulators
Updated
EUDAMED vs GUDID: key differences in scope, data models and UDI requirements, for manufacturers operating in both EU and US regulatory frameworks.
Read the guideAcross regulators
Updated
GUDID vs EUDAMED for regulatory data governance: how the US and EU databases differ and how to keep device data consistent.
Read the guide
Tell us how many DI records you maintain and how you submit them today. We will show you the ACKOMAS path for your case.